  • New 175L Growth Chambers Passed Testing And Sent To Kazakhstan
    July 25, 2022 New 175L Growth Chambers Passed Testing And Sent To Kazakhstan

    A new batch of growth chambers with a capacity of 175L has passed the test and has been sent to Kazakhstan.Innova has variety of growth chambers of different specifications to meet customer needs.

  • Temperature Control System for Benchtop Bioreactor
    July 15, 2022 Temperature Control System for Benchtop Bioreactor

    The temperature control methods of benchtop bioreactor mainly include: 1.Bottom electric heating + cooling water circulation cooling, this method is more conducive to observe the fermentation situation. 2.Electric blanket heating, cooling water circulation cooling, this method is evenly heated and easy to operate. 3.Jacketed water circulation temperature control, this method is more accurate in temperature control, with the largest heating area, suitable for animal cell culture.

  • CIP station for stainless steel fermentor
    July 01, 2022 CIP station for stainless steel fermentor

    Manual cleaning of stainless steel fermentor is difficult, an on-line automatic CIP cleaning system can be equipped to solve this problem. The CIP station includes water tank and alkali tank with heating function. The CIP cleaning program can be freely set according to the process, generally in the order of water washing, alkali washing, and water washing. Purified water is recommended for cleaning. A spray ball is installed inside the tank for spray cleaning. 100% fully cover of the tank surface, without blind spots and residue.

  • Sterile culture technology of fermentor
    June 21, 2022 Sterile culture technology of fermentor

    The fermentor should provide a strict sterile environment, including high-temperature and high-pressure sterilization of culture medium, fermentor and connecting pipeline before fermentation; air filtration for dry sterile air into fermentor; and sterile feeding during the fermentation process, etc.

  • INNOVA glassware washer cleaning effect for oily glassware
    June 13, 2022 INNOVA glassware washer cleaning effect for oily glassware

    Manual cleaning of oily glassware is difficult, INNOVA glassware can help users solve the problem easily and achieve excellent cleaning effect of oily glassware.

  • Operation process of fermentor
    June 06, 2022 Operation process of fermentor

    Fermentor should be strictly sealed during design and processing, resistant to steam sterilization, avoid dead corner, easy to clean, with good heat exchange performance. 1.After the fermentor is cleaned, add medium and close the tank lid tightly. Calibrate pH and DO electrodes and insert them into electrode ports, then tighten. The motor, pH electrode, DO electrode, defoaming electrode port are wrapped with tin foil, and air filter is installed at the air inlet. Clamp the connection pipe and sampling pipe with a clip. Control exhaust pipeline to open properly with screw clip, and wrap the exhaust pipeline with eight layers of gauze. 2.Sterilize the fermentor 3. After the fermentor is cooled down, connect the circuits of the motor, pH electrode, DO electrode, and defoaming electrode, and install the temperature electrode into the temperature measurement port. Connect the circulating water pipeline, turn on the water circulation, and set the temperature to automatic. Connect the other end of the air filter is to the aeration device, and switch on the flow meter is to let air enter the tank. 4.Enter the fermentation stage when reaching the required temperature. 1)Set the parameters of the fermentation process and calibrate the DO electrode to 100%. 2)Adjust the tank pressure to less than 0.02Mpa for inoculation, and immediately increase the tank pressure. 3)Switch the fermentor to the start state. 5.After the end of the fermentation stage, switch the fermentor to the end state, and obtain fermentation broth. 6.Rinse the tank with distilled water. After cleaning, add an appropriate amount of distilled water to soak the electrode (if the use interval is long, the electrode should be taken out and stored properly). Close all valves, close the control program, and switch off the main power.